Chimney Area Heat Load

Reference data and engineering information about chimney area heat load for combustion applications.

chimneyareaheatloadCalculator

Overview

Engineering reference data for Chimney Area Heat Load in combustion engineering.

Key Formulas

Heat Release

Q=m˙HVQ = \dot{m} \cdot HV

Fuel energy release rate.

Air-Fuel Ratio

AF=mairmfuelAF = \frac{m_{air}}{m_{fuel}}

Mass of air per mass of fuel.

Excess Air

EA=O221O2×100%EA = \frac{O_2}{21 - O_2} \times 100\%

From flue gas oxygen measurement.

Variables

SymbolDescriptionUnit
QQHeat release rateW
m˙\dot{m}Mass flow ratekg/s
HVHVHeating valueJ/kg
AFAFAir-fuel ratio
10 rows
Required chimney area as a function of boiler heat load capacity.
Boiler Capacity(kW)
Boiler Capacity(Btu/h)
Required Chimney Area(cm²)
Required Chimney Area(in²)
155100011518
237800015023
3511900020031
4615700025039
5819800030047
7023900035054
8127600040062
9331700045070
10435500050078
11639600055085

Source: engineeringtoolbox.com

Important Notes

The conversion factor between power units is:

1 kW=3412 Btu/h1 \text{ kW} = 3412 \text{ Btu/h}

Design Reminder: Always check and comply with requirements from your local building authorities and codes before finalizing your chimney design.