Copper Tube Supports
Reference data and engineering information about copper tube supports for piping systems applications.
coppertubesupports
Overview
Engineering reference data for Copper Tube Supports in piping systems.
Key Formulas
Continuity
Mass conservation in pipe flow.
Pressure Drop
Darcy-Weisbach equation.
Pipe Area
Cross-sectional area of a pipe.
Variables
| Symbol | Description | Unit |
|---|---|---|
| Pipe diameter | m | |
| Flow velocity | m/s | |
| Pressure drop | Pa | |
| Friction factor | — |
Copper Tube Support Spacing
The following table provides the maximum recommended spacing between supports for copper tubes in both horizontal and vertical runs.
15 rows
Size(mm) | Size(in) | Horizontal Run(m) | Horizontal Run(ft) | Vertical Run(m) | Vertical Run(ft) |
|---|---|---|---|---|---|
| 6 | 0.4 | 1.3 | 0.6 | 2 | |
| 8 | 0.6 | 2 | 0.9 | 3 | |
| 10 | 3/8 | 0.8 | 2.6 | 1.2 | 4 |
| 12 | 1 | 3.3 | 1.5 | 5 | |
| 15 | 1/2 | 1.2 | 4 | 1.8 | 6 |
| 22 | 3/4 | 1.2 | 4 | 1.8 | 6 |
| 28 | 1 | 1.5 | 5 | 2.4 | 8 |
| 35 | 1 1/4 | 1.8 | 6 | 3 | 10 |
| 42 | 1 1/2 | 1.8 | 6 | 3 | 10 |
| 54 | 2 | 1.8 | 6 | 3 | 10 |
| 67 | 2 1/2 | 2.4 | 8 | 3.7 | 12 |
| 76 | 3 | 2.4 | 8 | 3.7 | 12 |
| 108 | 4 | 2.4 | 8 | 3.7 | 12 |
| 133 | 5 | 3 | 10 | 3.7 | 12 |
| 159 | 6 | 3.7 | 12 | 3.7 | 12 |
Source: engineeringtoolbox.com
Example
For a 1" (28 mm) copper tube, the maximum distance between horizontal supports should be 1.5 meters (5 feet).