En 1075 Copper Tubes
Reference data and engineering information about en 1075 copper tubes for piping systems applications.
1075coppertubes
Overview
Engineering reference data for En 1075 Copper Tubes in piping systems.
Key Formulas
Continuity
Mass conservation in pipe flow.
Pressure Drop
Darcy-Weisbach equation.
Pipe Area
Cross-sectional area of a pipe.
Variables
| Symbol | Description | Unit |
|---|---|---|
| Pipe diameter | m | |
| Flow velocity | m/s | |
| Pressure drop | Pa | |
| Friction factor | — |
Material Properties
Temper Designations
Copper tubes according to EN 1057 are available in three material tempers, each with distinct mechanical properties:
3 rows
EN 1173 Designation | Common Term | Size Range(mm) | Tensile Strength(MPa) | Elongation min.(%) | Vickers Hardness(HV5) |
|---|---|---|---|---|---|
| R220 | annealed, soft | 6 – 54 | 220 | 40 | 40 – 70 |
| R250 | half hard | 6 – 66.7 | 250 | 20 | 75 – 100 |
| R290 | hard | 6 – 159 | 290 | 5 | 95 – 120 |
Source: EN 1057 / EN 1173
EN 1173 Property Letter Symbols
| Symbol | Property |
|---|---|
| A | Elongation |
| B | Spring bending limit |
| G | Grain size |
| H | Hardness (Brinell for castings, Vickers for wrought products) |
| M | (as) Manufactured, i.e. without specified mechanical properties |
| R | Tensile strength (e.g., R220 = 220 MPa) |
| Y | 0.2% proof strength |
Tube Dimensions
Plain Straight Tubes — R250 Half Hard & R290 Hard
15 rows
Nominal Outside Diameter(mm) | Tube Length(m) | Wall Thickness X(mm) | Wall Thickness Y(mm) |
|---|---|---|---|
| 6 | 3, 6 | 0.6 | 0.8 |
| 8 | 3, 6 | 0.6 | 0.8 |
| 10 | 3, 6 | 0.6 | 0.8 |
| 15 | 3, 6 | 0.7 | 1 |
| 22 | 3, 6 | 0.9 | 1.2 |
| 28 | 3, 6 | 0.9 | 1.2 |
| 35 | 3, 6 | 1.2 | 1.5 |
| 42 | 3, 6 | 1.2 | 1.5 |
| 54 | 3, 6 | 1.2 | 2 |
| 67 | 3, 6 | 1.2 | 2 |
| 76 | 3, 6 | 1.5 | 2 |
| 108 | 3, 6 | 1.5 | 2.5 |
| 133 | 3, 6 | 1.5 | — |
| 159 | 3, 6 | 2 | — |
| 219 | 6 | 3 | — |
Source: EN 1057
Plain Coils — R220 Annealed (Soft)
2 rows
Nominal Outside Diameter(mm) | Coil Length(m) | Wall Thickness(mm) |
|---|---|---|
| 15 | 25 | 1 |
| 22 | 25 | 1.2 |
Source: EN 1057
Chrome Plated Tubes — R250 Half Hard & R290 Hard
6 rows
Nominal Outside Diameter(mm) | Tube Length(m) | Wall Thickness(mm) |
|---|---|---|
| 15 | 2, 3 | 0.7 |
| 22 | 2, 3 | 0.9 |
| 28 | 3 | 0.9 |
| 35 | 3 | 1 |
| 42 | 3 | 1 |
| 54 | 3 | 1 |
Source: EN 1057