Skip to main content
Speclore

Hydrostatic Test Pressure Flanges

Reference data and engineering information about hydrostatic test pressure flanges for fluid mechanics applications.

hydrostatictestpressureflanges

Overview

Engineering reference data for Hydrostatic Test Pressure Flanges in fluid mechanics.

Key Formulas

Reynolds Number

Re=ρvDμRe = \frac{\rho v D}{\mu}

Ratio of inertial to viscous forces — determines flow regime.

Bernoulli's Equation

P+12ρv2+ρgh=constP + \frac{1}{2}\rho v^2 + \rho g h = \text{const}

Conservation of energy for steady, inviscid, incompressible flow.

Continuity Equation

A1v1=A2v2A_1 v_1 = A_2 v_2

Conservation of mass for incompressible flow.

Darcy-Weisbach

ΔP=fLDρv22\Delta P = f \frac{L}{D} \frac{\rho v^2}{2}

Pressure drop due to friction in a pipe.

Variables

SymbolDescriptionUnit
ReReReynolds number
ρ\rhoFluid densitykg/m³
vvFlow velocitym/s
DDCharacteristic dimensionm
μ\muDynamic viscosityPa·s
PPPressurePa
ffDarcy friction factor

Hydrostatic Test Pressure Reference Table

The table below provides hydrostatic test pressures in psig for common flanged fittings based on ASTM specifications and pressure class ratings.

8 rows
Hydrostatic test pressures (psig) for flanged fittings by ASTM specification and pressure class.
ASTM Specification
Class 150(psig)
Class 300(psig)
Class 400(psig)
Class 600(psig)
Class 900(psig)
Class 1500(psig)
Class 2500(psig)
A105, A216-WCB, A350-LF2, A515-70, A516-70, A537-C1.1, A675-70, A672-B70, A672-C70, A696 Grade C450112515002225335055759275
A106-C, A203-B, A203-E, A216-WCC, A350-LC3, A352-LCC, A352-LC2, A352-LC3450112515002250337556259375
A203-A, A203-D, A352-LCB, A515-65, A516-65, A675-65, A672-B65, A672-C65400105014002100315052258700
A106-B, A350-LF1, A515-60, A516-60, A672-B60, A672-C60, A675-60, A696 Grade B37595012501875277546507725
A182-F1, A204-A, A204-B, A217-WC1, A352-LC1, A691-CM70400105014002100315052258700
A182-F2, A204-C, A217-WC4, A217-WC5, A691-CM75450112515002250337556259375
A182-F12, A182-F11, A217-WC6, A387-11C1.2, A739-B11450112515002250337556259375
A182-F304, A182-F304H, A240-304, A240-304H, A312-TP304, A312-TP304H, A351-CF3, A351-CF8, A479-304, A479-304H425110014502175325054009000

Source: Engineering Toolbox

Interactive Charts

Hydrostatic test pressures (psig) for flanged fittings by ASTM specification and pressure class.

References