Overview

Engineering reference data for Safety Valves High Pressure Steam in fluid mechanics.

Key Formulas

Reynolds Number

Re=ρvDμRe = \frac{\rho v D}{\mu}

Ratio of inertial to viscous forces — determines flow regime.

Bernoulli's Equation

P+12ρv2+ρgh=constP + \frac{1}{2}\rho v^2 + \rho g h = \text{const}

Conservation of energy for steady, inviscid, incompressible flow.

Continuity Equation

A1v1=A2v2A_1 v_1 = A_2 v_2

Conservation of mass for incompressible flow.

Darcy-Weisbach

ΔP=fLDρv22\Delta P = f \frac{L}{D} \frac{\rho v^2}{2}

Pressure drop due to friction in a pipe.

Variables

SymbolDescriptionUnit
ReReReynolds number
ρ\rhoFluid densitykg/m³
vvFlow velocitym/s
DDCharacteristic dimensionm
μ\muDynamic viscosityPa·s
PPPressurePa
ffDarcy friction factor

Safety Valve Capacities

The following tables provide safety valve capacities for high-pressure steam systems at different operating pressures. Capacities are given in mass flow rate and equivalent boiler output. Always consult manufacturer documentation for final design.

Steam Pressure: 10 bar (1000 kPa / 150 psi)

9 rows
Safety valve capacities for steam at 10 bar (1000 kPa). Latent heat of saturated steam: 1999 kJ/kg.
Pipe Size (in)
Pipe Size (DN)(mm)
Capacity(kg/h)
Capacity(lb/h)
Maximum Boiler Output(kW)
Maximum Boiler Output(Btu/h)
1/215220498122426786
3/4204721070262916990
12582718754591606875
1 1/432142132227892761254
1 1/2402058466811434000476
2503065695417025959578
2 1/265514411670285610001190
380710816124394713818268
41001369431067760426624419

Source: engineeringtoolbox.com

Steam Pressure: 7 bar (700 kPa / 100 psi)

9 rows
Safety valve capacities for steam at 7 bar (700 kPa). Latent heat of saturated steam: 2046 kJ/kg.
Pipe Size (in)
Pipe Size (DN)(mm)
Capacity(kg/h)
Capacity(lb/h)
Maximum Boiler Output(kW)
Maximum Boiler Output(Btu/h)
1/21515934690304480
3/420342743194653840
12559913023401145760
1 1/432103022385851969440
1 1/2401792324210182852960
2502222482712634247760
2 1/2653730810121207128880
38051531119329299849840
4100992921566564318978080

Source: engineeringtoolbox.com

Steam Pressure: 3 bar (300 kPa / 50 psi)

9 rows
Safety valve capacities for steam at 3 bar (300 kPa). Latent heat of saturated steam: 2133 kJ/kg.
Pipe Size (in)
Pipe Size (DN)(mm)
Capacity(kg/h)
Capacity(lb/h)
Maximum Boiler Output(kW)
Maximum Boiler Output(Btu/h)
1/2157919347176016
3/420169414100377568
125296726175662112
1 1/43250912483021138176
1 1/24073718074371647984
250109926956512457840
2 1/2651844452210934124064
3802547624815095698176
4100490712038290710978656

Source: engineeringtoolbox.com

Pressure Unit Conversion

A fundamental conversion for pressure in safety valve calculations is:

1N/m2=1Pa=1.4504×104lb/in2(psi)=1×105bar1 \, \text{N/m}^2 = 1 \, \text{Pa} = 1.4504 \times 10^{-4} \, \text{lb/in}^2 \, (\text{psi}) = 1 \times 10^{-5} \, \text{bar}

Interactive Charts

Steam safety valves capacity chart

Low Pressure Steam Safety Valves - Capacities

Safety valve capacities for steam at 3 bar (300 kPa). Latent heat of saturated steam: 2133 kJ/kg.

References