Skip to main content
Speclore

Arithmetic logarithmic mean température

Reference data et engineering information about arithmetic logarithmic mean température pour transfert de chaleur applications.

arithmeticlogarithmicmeantemperature

Overview

Engineering reference data for Arithmetic Logarithmic Mean Temperature in heat transfer.

Key Formulas

Fourier's Law

q=kTq = -k \nabla T

Heat flux proportional to temperature gradient.

Convective Heat Transfer

Q=hA(TsT)Q = hA(T_s - T_\infty)

Heat transfer between surface and fluid.

Stefan-Boltzmann Law

q=εσT4q = \varepsilon \sigma T^4

Radiative heat flux from a surface.

Thermal Resistance

Rth=LkAR_{th} = \frac{L}{kA}

Resistance to heat conduction.

Variables

SymbolDescriptionUnit
qqHeat fluxW/m²
kkThermal conductivityW/(m·K)
hhConvection coefficientW/(m²·K)
TTTemperatureK
ε\varepsilonEmissivity
σ\sigmaStefan-Boltzmann constant5.67×10⁻⁸ W/(m²·K⁴)

References