Skip to main content
Speclore

Saturated vapeur table

Reference data et engineering information about saturated vapeur table pour vapeur et condensate applications.

saturatedsteamtableTableau de données

Overview

Engineering reference data for Saturated Steam Table in steam condensate.

Key Formulas

Steam Quality

x=mvmtotalx = \frac{m_v}{m_{total}}

Mass fraction of vapor in two-phase mixture.

Enthalpy of Wet Steam

h=hf+xhfgh = h_f + x \cdot h_{fg}

Specific enthalpy of wet steam.

Flash Steam

mflash=mliquidhfhf2hfg2m_{flash} = m_{liquid} \frac{h_f - h_{f2}}{h_{fg2}}

Steam generated when condensate flashes to lower pressure.

Condensate Load

mc=Qhfgm_c = \frac{Q}{h_{fg}}

Condensate generated by heat transfer.

Variables

SymbolDescriptionUnit
xxSteam quality
hfh_fEnthalpy of saturated liquidkJ/kg
hfgh_{fg}Latent heat of vaporizationkJ/kg
hhSpecific enthalpykJ/kg
QQHeat transfer ratekW