Orifice nozzle venturi
Reference data e engineering information about orifice nozzle venturi para fluid mechanics applications.
orificenozzleventuriCalculadoraTabela de dados
Overview
Orifice plates, nozzles, and Venturi meters are differential pressure flow meters. They create a constriction that increases velocity and decreases pressure, allowing flow rate calculation from the pressure differential.
Key Formulas
Flow Rate
Discharge through a differential pressure meter.
Beta Ratio
Ratio of throat diameter to pipe diameter.
Variables
| Symbol | Description | Unit |
|---|---|---|
| Volume flow rate | m³/s | |
| Discharge coefficient | — | |
| Throat area | m² | |
| Pressure differential | Pa | |
| Fluid density | kg/m³ | |
| Diameter ratio | — |
Reference Data
4 linhas
Meter Type | Typical C_d | Beta Range | Accuracy | Pressure Loss |
|---|---|---|---|---|
| Orifice Plate | 0.6 | 0.2 – 0.75 | ±1–2% | High |
| Venturi Meter | 0.98 | 0.3 – 0.75 | ±1% | Low |
| Flow Nozzle | 0.96 | 0.2 – 0.8 | ±1–2% | Medium |
| Wedge Meter | 0.65 | — | ±2–5% | Medium |
Fonte: engineeringtoolbox.com